Manual S equipment selection

Manual S equipment selection and heat pump sizing that fits the house

Tradewright matches real equipment to the Manual J load at your design temperature, checks it against Manual S sizing limits, and shows why each unit made the cut.

Manual S is the ACCA method for choosing heating and cooling equipment once the Manual J load is known. It checks capacity at the actual design conditions, not the nameplate, and limits oversizing. Tradewright applies Manual S to real equipment, including cold-climate heat pump capacity at your design temperature, during the sales visit.

Illustration of the Tradewright interface · Equipment capacity checked at design temperature

How equipment selection works

  1. Step 1: Start from the load

    The room-by-room Manual J heating and cooling loads, and the design temperatures behind them, carry straight into selection.

  2. Step 2: Check real equipment

    Candidate units are checked on their capacity at design conditions, so a heat pump is judged on what it delivers on the coldest design day.

  3. Step 3: Apply Manual S limits

    Equipment that is too small, or oversized beyond Manual S limits, is ruled out, and the reason is recorded.

  4. Step 4: Hand off to comparison

    The units that fit move into the whole-system comparison and the Good/Better/Best proposal.

Who it helps

  • Heat pump contractors

    Size cold-climate heat pumps on capacity at design temperature, not nominal tons.

  • Comfort advisors

    Recommend equipment with an engineered reason, without memorizing performance tables.

  • Technical leads

    See which units were considered and why each one was accepted or ruled out.

  • Boiler and furnace replacements

    Stop replacing like for like when the existing unit was oversized from the start.

  • Rebate jobs

    Produce an equipment selection sheet to go with the Manual J report.

Equipment selection compared

Equipment selection in Tradewright compared with rules of thumb and load-calc-only tools
Rules of thumbLoad-calc-only toolsTradewright
Sized from a Manual J loadNoYesYes
Capacity checked at design temperatureNoSomeYes
Manual S oversizing limits appliedNoSomeYes
Shows ruled-out equipment and whyNoNoYes
Flows into a priced proposalNoNoYes

Columns describe software categories and common practice, not specific vendors.

Questions

What is Manual S?

Manual S is the ACCA procedure for selecting residential heating and cooling equipment. It takes the Manual J load and checks equipment capacity at the actual design conditions, with limits on how far equipment may be oversized or undersized.

How does Tradewright size a heat pump?

Tradewright compares the Manual J heating and cooling loads with each heat pump's capacity at your design temperature, rather than its nominal tonnage. Units that cannot carry the load, or that exceed Manual S limits, are ruled out with the reason shown.

Does it handle cold-climate heat pumps?

Yes. Cold-climate heat pump selection is checked on capacity at the design temperature for the location, which is where nominal ratings are most misleading.

Which equipment types can it select?

Heat pumps, mini-splits, furnaces, air conditioners, boilers and dual-fuel systems.

Can I see why a unit was rejected?

Yes. Ruled-out equipment stays visible with a short explanation, such as insufficient capacity at design temperature or oversizing beyond Manual S limits.

Can I still choose a different unit?

Yes. Tradewright engineers the options; you decide how to sell. Your team can review the selection and adjust it before the proposal is built.

See heat pump sizing at design temperature on a real home.

A 20-minute demo on a real home in your territory.